Avoid vibrations. | Do not cover the laser window. | Avoid moving objects and light sources in the detection field. | Avoid presence of smoke in the detection field |
Avoid condensation. | Avoid exposure to sudden and extreme temperature changes. | Keep the sensor permanently powered in environment where the temperature can descend below -10°. |
The door control unit and the door cover profile must be correctly earthed. | Only trained and qualified personnel may install and setup the sensor. | Always test the good functioning of the installation before leaving the premises. |
Clean the laser window with compressed air. If needed, wipe only with a soft, clean and damp microfibre cloth. | Do not use dry or dirty towels or aggressive products to clean the laser window. | Avoid direct exposure to high pressure cleaning. | The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel. |
Cover | Mounting base | Bluetooth® LED (white) | ||||
Red push button | Radar antenna | BLUESPIN connectors | ||||
White push button (+) | BLUESPIN LED (white) | Power cable | ||||
Black push button (-) | Main LED (multi color) | BLUESPIN cable | ||||
DIP-switch | Sidescreen safety : right side (red) | |||||
Connectors | Sidescreen safety : left side (red) |
Safety | LED blinks | ||
Opening | LED blinks slowly | ||
Bluetooth® or BLUESPIN | LED blinks quickly | ||
LED is off | LED blinks x times | ||
LED blinks red-green |
Note | |
---|---|
The ORASCAN sensor must be paired with another ORASCAN using the supplied BLUESPIN cable. ORASCANS can be connected to a door controller using previously installed IXIO cables. Please refer to the application note. |
| |
| |
| |
| |
| |
| |
| |
| |
|
Power supply: 12-30VDC | |
Opening: Main Orascan | |
Safety: Door threshold | |
Opening: Current source | |
Safety: Door sidescreen | |
Test Safety: Door sidescreen | |
Opening: Secondary Orascan |
Caution | |
---|---|
External electrical sources must ensure double insulation from primary voltages. |
2 Electronic relays galvanic isolation (polarity free)
| ||
1 Galvanically isolated current source
| ||
1 safety pulse input :
- Positive pulse: 2 K to ground - Negative pulse: 470 R to + sensor power supply
| 1 safety pulse output:
- Standby: Pulse from V to ground - Detection: V Supply
| |
1 Electronic relay galvanic isolation (polarity free)
| ||
1 Test input :
|
DIP 1 : MOUNTING SIDE | |
ON : | INSIDE |
OFF : | OUTSIDE* |
DIP 2 : ESCAPE ROUTE | |
ON : | RADAR OUTPUT > FREQUENCY + CURRENT |
OFF : | RADAR OUTPUT > NO* |
Switch to ON to ESCAPE ROUTE to use the radar output in frequency or current source mode for an emergency exit application. |
DIP 3 : SIDESCREEN SAFETY | |
ON : | SIDECREEN SAFETY ON 2 CURTAINS |
OFF : | NO SIDESCREEN SAFETY* |
Switch to ON to activate both laser curtains in the sidescreen field. |
DIP 4 : TEACH-IN MODE | |
ON : | MANUAL TEACH-IN |
OFF : | AUTOMATIC TEACH-IN* |
Switch to MANUAL to position the laser curtains and to define the safety area limits manually. |
DIP 5 : BLUESPIN CHAIN END (ON*/ OFF) | |
Switch OFF if two BLUESPIN cables are connected on this ORASCAN module. |
*Factory Values |
After changing a DIP- switch, the main LED blinks orange. A long push on the red push button confirms the settings. |
The service mode deactivates the safety detection during 15 minutes and can be useful during an installation, a mechanical teach-in of the door or maintenance work. To enter the service mode, push on the red push button for > 3 seconds. When the sensor is in service mode, all safety-related LEDs are OFF To exit the service mode, push the red push button again for > 3 seconds. The service mode is deactivated automatically when launching a teach-in. |
Use the white button to increase the field size and the black button to decrease the field size.
Wide mode: press the black button 3s, when the LED turns purple, press the white one.
Narrow mode: press the black button 3s, when the LED turns purple, press the black one.
Note | |
---|---|
- Make sure the door operates in summer mode (full opening) during the teach-in. - Make sure you and anyone else are outside the detection field during the teach-in process. If people are inside the detection field, the sensor may not work as expected. - If the moving panels have no metallic frame, activate the "fog & full glass filter" with the mobile app (safety settings tab) and cover their edges from top to bottom with a large paper tape (at least 3cm wide). This strip can be removed once the teach-in is finished |
|
|
| ||||
|
You can adjust the laser curtains and set up the detection zone manually.
| ||||
| ||||
| ||||
| ||||
| ||||
|
|
|
Scan the QR code or open the following link to download the mobile application. https://l.ead.me/belDmx |
At power ON or after a power cycle, the Bluetooth® is activated for 30 min and the Bluetooth® LED is flashing white. | |
Open the Orascan mobile app and connect to the sensor. The password is indicated on the Bluetooth® notice contained in the packaging. When the smartphone is pairing with the sensor, the Bluetooth® LED is flashing quickly. | |
Once paired, the Bluetooth® LED is ON. |
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by BEA sa is underlicense. Other trademarks and trade names are those of their respective owners |
Factory values | Excludes compliance to EN 16005 & DIN 18650 | Not allowed in emergency exits | Excludes compliance to DIN 18650 |
Opening | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Field Shape | Field Size | Output | Immunity | Direction | Radar door filter | Hold time | Redirection | Output Control | Current Output Power | |
0 | OFF | 0.5s | OFF | 5% | ||||||
Narrow | 1 | NO | 1 | Bi | OFF | 1s | Motion or VOB | ON | 10% | |
Wide | 2 | NC | 2 | Uni | Low | 2s | Motion only | AUTO | 15% | |
3 | Frequency | 3 | PRM Uni | Medium | 3s | VOB only | 20% | |||
4 | Inv. Frequency | 4 | Away Uni | High | 4s | Motion or VOB or threshold presence | 25% | |||
5 | Current | 5 | PRM Away Uni | 5s | Motion or VOB or presence | 30% | ||||
6 | Escape Route | 6 | Shop bi | 6s | Motion & threshold presence | 35% | ||||
7 | 7 | Shop Uni | 7s | Motion & presence | 40% | |||||
8 | 8 | Shop PRM | 8s | 45% | ||||||
9 | 9 | 9s | 50% |
Safety | ||||||
---|---|---|---|---|---|---|
Presence Time | Fog & full glass door filter | Immunity | Min. Object Size | Horiz. Uncovered Zone | Background | Antimasking |
OFF | 3cm | OFF | OFF | |||
15s | ON | 1 | 5cm | 2cm | ON | ON |
30s | 2 | 10cm | 4cm | |||
1min | 3 | 15cm | 6cm | |||
2min | 4 | 20cm | 8cm | |||
5min | 5 | 25cm | 10cm | |||
10min | 6 | 30cm | 12cm | |||
20min | 7 | 35cm | 14cm | |||
60min | 8 | 40cm | 16cm | |||
infinite | 9 | 45cm | 18cm |
Safety at closing | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Look-through | Output Config. | External Monitoring | Output Control | External Monitoring Logic | ||||||
OFF | OFF | OFF | High active | |||||||
Dynamic | NO | ON | ON | Low active | ||||||
Static | NC | AUTO | AUTO |
Safety at opening | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of curtains | Output Config | Vertical Uncovered Zone | External Monitoring | Output Control | External Monitoring Logic | |||||
0 | OFF | OFF | High active | |||||||
1 | NO | 2cm | ON | ON | Low active | |||||
2 | NC | 4cm | AUTO | AUTO | ||||||
6cm | ||||||||||
8cm | ||||||||||
10cm | ||||||||||
12cm | ||||||||||
14cm | ||||||||||
16cm | ||||||||||
18cm |
Auxiliary output | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Activation Condition | Hold Time | Output Config. | Output Control | Field Size | ||||||
OFF | OFF | OFF | 0 | |||||||
Bell | 0.05s | NO | ON | 1 | ||||||
Presence | 0.1s | NC | AUTO | 2 | ||||||
Presence center | 0.25s | 3 | ||||||||
Presence Sides | 0.5s | 4 | ||||||||
VOB | 0.75s | 5 | ||||||||
Motion | 1s | 6 | ||||||||
Secondary Module | 1.5s | 7 | ||||||||
2s | 8 | |||||||||
5s | 9 |
Supply voltage | 12 – 30V DC +/-10% External electrical sources must ensure double insulation from primary voltages. |
Max Power consumption | <5W |
Mounting Height | 2m to 3,5m |
Temperature range | -25°C to +55°C; 0-95% relative humidity, non condensing |
Vibrations | <2G |
Degree of protection | IP54 (IEC/EN 60529) |
Material | PC/ASA |
Weighted emission sound pressure level | < 70 dB (A) |
Detection mode | Motion | Presence |
Technology | Microwave doppler radar
| LASER scanner, time-of-flight measurement
|
Safety standards | EN ISO 13849-1 PL «d» CAT. 2 EN 16005 (emergency exits) DIN 18650-1 (emergency exits) AutSchR (only applicable for radar output in frequency mode and current source output) | EN ISO 13849-1 PL «d» CAT. 2 EN 16005 (protective devices) DIN 18650-1 (protective devices) EN 12978 |
Bluetooth ® | Operating bandwidth: 2402 MHz – 2480 MHz Maximum transmitted power: 12 dBm |
Specifications are subject to change without prior notice. All values measured in conditions and with a temperature of 25°C |